| new products | ||
| Nice
and easy does it Amacoil Inc., Aston, Pa. |
|
|
|
|
||
|
Submers- ible pump KSB Aktienge-sellschaft, Frankenthal, Germany |
The UPA 100 C series of submersible
borehole pumps is designed for use in water supply, irrigation, lowering
groundwater levels, pressure boosting, and fire protection applications.
Stainless steel pump units handle water with a solids content of 50 grams
per cubic meter. Integrated anti-blockage check valve prevents pipe discharge
when switch is in the off position, avoiding damage due to reverse rotation.
Single- and three-phase canned motors are available. Intermediate bearings
at each pump stage prevent potential shaft misalignment, according to the
company. |
|
|
|
||
|
Industrial safety
IFM Efector Inc., Exton, Pa. |
The industrial safety networking system integrates standard mechanical safety devices into most standard PLCs and higher network levels. A two-wire flat cable carries power and signal to each safety device, eliminating the need to wire each device back to the main control cabinet individually. The Safety at Work system comprises a safety monitor that evaluates the transmission of dynamic code sequences stored in every safety module and a control platform interface. These translate safety messages throughout the network. Safety input modules and e-stop buttons interface with mechanical binary switching components in the field. During operation, the monitor compares the target sequence with safety module sequence. The monitor switches to the safe state if safety module provides a wrong sequence. The system functions with most PLCs. The Safety at Work system is TUV and BIA approved and rated category 4 according to EN-954-1. | |
|
|
||
|
Steam trap Nicholson Steam Trap, Walden, N.Y. |
The Sanitizer NTD230L Thermodynamic Steam Trap features stainless steel construction and internal and external surface finishes of 32 Ra down to 10 Ra. The self-draining sanitizer resists freezing, puddling and bacterial growth and fits 1/2- and 3/4-inch clamps. Heat numbers are stamped into the body. | |
|
|
||
|
Outage recorder |
A new sequence-of-events input module
for power systems is designed for the Allen-Bradley ControlLogix control
platform. The module can record the time of a power failure, as soon as
the breakers open and can monitor a number of input points. Rockwell says
the module can distinguish among events that occur within 100 microseconds
of each other. |
|
|
|
||
|
Mini isolation valves Bio-Chem Valve Inc., Boonton, N.J. |
The company says its miniature solenoid valves made of perfluoroelastomer and PEEK will stand up to aggressive and particulate-laden fluids, and will protect the integrity of high-purity fluids. They are available in two-way and three-way configurations. Bio-Chem will customize valves for original equipment makers. Choices of resin include PTFE and PPS. Bio-Chem will make the valves available separately or integrate them into a manifold for customers. | |
|
|
||
|
Small switch |
The company has come out with its smallest and most sensitive magnetically operated reed switch. The HSR-0025 is designed to respond to the need for mini-components in used in medical, aerospace, industrial, electronics, and other applications. Specific applications for the switch within the medical and healthcare markets include use in hearing aids, pacemakers and other implantable devices, defibrillators, surgical instruments, and test/diagnostic equipment. The oval-shaped glass body of the HSR-0025 switch measures 4.06 mm (0.16 in.) long, 1.22 mm (0.048 in.) wide, and 0.89 mm (0.035 in.) high. | |
|
|
||
| Front
ring adapter EAO Switch Corp., Milford, Conn. |
|
|
|
|
||
|
Accelero- meter switch Columbia Research Laboratories Inc., Woodlyn, Pa. |
The Model SS-108 force balance accelerometer switch can control, safeguard, or warn of undesirable conditions in dc and low-frequency acceleration. The switch's contacts can be configured to trigger in one or both directions along the sensitive axis, at specified g levels within a selected operating range. The solid state relay switching capacity is 500 mA at 60 V dc and comes with normally open or normally closed contacts. | |
|
|
||
|
Conductive cable carriers Igus Inc., East Providence, R.I. |
The System E6 line of cable carriers
is designed for applications that require precise operation, free of vibration.
The short pitch and a plastic link design of the EDS Energy Chains are suitable
for printing machinery, measurement equipment, cutting systems, and cleanrooms.
Conductive material eliminates the potential for sparks. |
|
|
|
||
|
Phase rotation meter AEMC Instruments, Foxborough, Mass. |
Model PR-1 is a phase rotation meter
designed to identify both phase sequence on three-phase systems and open/de-energized
systems. The meter can be used when installing rotating machinery motors
and when checking generator output. Test leads are permanently attached
and have proof separators. The instrument is rated EN 61010, cat. III. |
|
|
|
||
|
Four-in- one motor system Animatics Corp., Santa Clara, Calif. |
The ServoStep is an integrated stepper motor that combines a 50-pole step motor, motion controller that uses software downloaded from the Internet, drive amplifier, and encoder. The motion control system delivers continuous torque capability of up to 650 oz.-in. and a nominal speed of 2,200 rpm. | |
|
|
||
|
Fabric duct filter DuctSox, Dubuque, Iowa |
The Final Filter is a replaceable in-duct air filter for fabric duct that increases indoor air quality and energy savings, while reducing outdoor air requirements and building maintenance. Designed for supplementing primary filter systems in new or retrofit buildings with DuctSox air dispersion, the Final Filter is cone-shaped and readily zippered within minutes into a fabric duct system at the inlet. The multilayer custom filter media were developed to withstand pressure loading while allowing depth loading. | |
|
|
||
|
Rotary screw com-pressors Kaeser Compressors, Fredericksburg, Va. |
Kaeser has added the CSD 100 and CSD 125 to its line of rotary screw compressors. The entire line of compressors is available in flows from 188 to 592 cfm and pressures to 217 psig. The CSD models are designed for energy efficiency, reliability, minimal maintenance, and space savings. The CSD models are true direct drive compressors with an optimized Sigma Profile air end connected directly to the motor via a maintenance-free, one-to-one drive coupling for efficiency. | |
|
|
||
|
Go with the flow Sierra Instruments Inc., Monterey, Calif. |
|
|
|
|
||
|
A foil for lightning Dexmet Corp., Branford, Conn. |
MicroGrid Precision expanded foil offers lightning protection when bonded to composite aircraft surfaces or other materials with low innate conductivity. Highly controlled expanded open-area pattern of the lightweight, flexible foils meets specific conductivity requirementsup to 200,000 amps. The material conforms to contours during manufacture and repair. Single-unit structure cannot unravel. | |
|
|
||
|
Replace- able ceiling modules Camfil Farr, Riverdale, N.J. |
An updated line of roomside replaceable PharmaSeal ducted ceiling modules provides cleanroom level air filtration to pharmaceutical and biotechnology facilities. They may also be installed in other settings where clean space is a manufacturing or health-related requirement, including medical, food processing, photographic, and microelectronics facilities. The PharmaSeal module is assembled using ASME welding procedures. A guillotine-type control damper has heavy-duty adjustable linkage for precise roomside airflow adjustment and room air balance. | |
|
|
||
|
Accelero- meters Kistler Instrument Corp., Amherst, N.Y. |
Simultaneously measuring vibration
in three mutually perpendicular axes, this newly designed accelerometer
incorporates smart circuit technology. The PiezoSmart circuitry permits
reading a self-generating data sheet, and writing to the internal sensor
memory is enabled. Additionally, the 8762(X) M10 Series provides conventional
analog operation in the low impedance, voltage mode. The series of three
models has measuring ranges of 5 g, 10 g, and 50 g. The 20 mm cube accelerometer
uses a ceramic shear sensing element and a ground isolated housing. |
|
|
|
||
|
Linear drive Amacoil Inc., Aston, Pa. |
Uhing Co., a subsidiary of Amacoil, has re-engineered its Model RG 40 mm rolling ring drives to provide automatic reversal, without programming or electronics, while traveling at linear speeds of up to 0.6 m/s (0.6565 yards/second) more than twice as fast as previous Uhing 40 mm drives. At linear speeds exceeding 0.6 m/s, the drives will still automatically reverse without clutches, cams, or gears, provided the assembly is fitted with a slowdown mechanism that slightly reduces linear speed before reversal. Previously available only as an option, Uhing's free movement lever is standard on the new 40 mm drives. | |
|
|
||
|
Flam- mability analyzers Control Instruments Corp., Fairfield, N.J. |
The cost of natural gas used for heating
process ovens and dryers can be substantial. The use of PrevEx flammability
analyzers can lower oven and dryer heating costs in processes that use solvents.
Use of PrevEx analyzers, according to the company, reduces ventilation air
without affecting existing production rates or violating National Fire Protection
Association safety directives; boosts production speed without increasing
air or fuel costs; reuses rather than expels some of a hot exhaust stream
back into an oven zone; and reduces oven exhaust rates to lower demand on
destruction oxidizers. |
|
|
|
||
|
Filter out fungus Universal Air Filter Co., Sauget, Ill. |
The filter media used to construct WrapAround Air Filters for medical electronics enclosure now incorporate flame-resistant coatings and anti-microbial additives that resist fungal growth. The stainless steel or aluminum frames are available with finishes to protect against corrosion and integrate a series of reinforcing intermediate panes that lend media support. The company offers customized pane sizes and frame thicknesses. | |
|
|
||
|
Neutralize static charges Exair Corp., Cincinnati, Ohio |
|
|
|
|
||
|
Water treatment system Metalfab Inc., Vernon, N.J. |
Loss-of-Weight Feeders and PosiBins can be used as a system to meter lime in water treatment applications at a rate of 105 lbs. per three minutes with an accuracy between 0.25 and 0.50 percent of required batch from each feeder. According to the company, such a system decreases material waste while automating the lime storage and feeding processes. | |
|
|
||